Introduction

PoissonNMF is an ImageJ plugin that allows to decompose spectrally resolved fluorescence microscopy data into the contributions of the labels. It can be used without known reference spectra and estimates these spectra using non-negative matrix factorization [1], suitably modified for shot-noise dominated data. In cases when reference spectra are inaccurately known, the inaccurate spectra can be refined to yield a better decomposition of the data. The details of the algorithm are discussed in [2]. Step-by-step tutorial using an example with 3 dyes can be found here. If you use PoissonNMF in a publication, please cite:
Blind source separation techniques for the decomposition of multiply labeled fluorescence images. RA Neher, M Mitkovski, F Kirchhoff, E Neher, FJ Theis, A Zeug, Biophysical journal 96 (9), 3791-3800

Installation

To install the plugin, copy the PoissonNMF_.jar file into the plugin folder of your ImageJ distribution. The plugin allows to save spectra to a library and reuse them for future analysis, see below. For this feature to work, the spectra have to be saved in a folder named SpectraLibrary at the top level of the plugins folder of the ImageJ distribution. Alternatively, the source code of the all our imageJ projects can be obtained from our git server.
top

Input data

PoissonNMF expects an image stack or an hyperstack with the default ImageJ order of dimensions, i.e. the 3rd dimension of the stack has to correspond to different spectral channels, whereas the 4th and 5th dimensions could be depth or time. The stack is internally converted to a 32bit stack, such that the necessary memory can increase quite drastically. If no stack is provided, the plugin asks the user to specify the type of data to NTF_data_selectbe used (Regular Stack, Zeiss LSM data, Leica SP2 data) and then displays and open dialog. In case of Zeiss LSM data and Leica SP2 data, the plugin attempts to read the channel wavelength from the meta data provided by these formats.
top

Workflow

The analysis of an image stack with poissonNMF proceeds in a one dimensional fashion. The user is prompted for necessary and optional input using several dialog windows, which are going to be explained in the following. Most values of in the dialog boxes are preset to default values or those of the previous run.
top

Number of sources

Upon invoking poissonNMF from the plugin menu, the user is asked for the number of nosourceslabels that contribute to the image stack. This number is restricted to the range 2-10. In practice, more than 4 sources will rarely yield satisfactory results.
top

Parameter dialog

After specifying the number of sources, the user is prompted for parameters needed for preprocessing of the data, initial conditions and runtime options.

Number of iterations and subsampling.
To speed up convergence, the poissonNMF applies the update rules in several stages
to subsamples of the data. The estimates for the spectra obtained with one subsamble
are used as initial conditions for the next larger subsample. The number of such stages can be specified in subsamples field. From one subsample to the next, the amount of data used by the algorithm is increased by a factor of 10 in such a way that the last subsamples comprises the entire data set. The total number of times the iterative update rules are applied to the data can also be specified. The number of iterations for larger subsamples is smaller (a factor 2 between successive subsamples).

Segregation bias.
In some circumstances, in particular when spectra overlap strongly, the NMF solution is not unique and NMF tends to parameterDialogestimate too narrow spectra and incompletely separated sources. This tendency can be counteracted by a segregation bias that penalizes the overlap of the estimated label distributions. Suitable weights of the segregation bias are of order 1. Too high segregation bias will yield in a faulty decomposition. To turn off the segregation bias, set its weight to zero.

Saturation threshold.
Saturated or nearly saturated pixels have distorted emission spectra and therefore have to be excluded from the analysis. If the signal in any channel at a certain pixel is above this parameter value, the pixel is excluded.

Background threshold.
Very faint pixels carry little information and are likely dominated by noise, autofluorescence or similar contaminants. It is therefore advisable to limit the spectra estimation to reasonably strong pixels. Any pixel, whose intensity is below this threshold in every channel is therefore excluded. This thresholding is applied after the constant background is substracted.

Background spectrum and initial spectra.
Before the algorithms can process the data, the background spectrum has to be substracted and spectra initialized with a set of start spectra. Both, background and spectra can be specified in a variety of ways, that can be selected from a pull-down menu. The choices for the background are:

  • Minimal values: the minimum across the image is determined for each channel.
  • ROI selection: the user is prompted for a ROI
    which contains background signal only.
  • Manually: the user is prompted for the background strength in each channel
  • Flat: the user prompted for one number, which is assumed to describe the background in all channels.

Similar choices are available for the initial spectra:

  • Gaussian: The spectra are initialized with a Gaussian with predefined width and position.
  • ROI selection: the user is prompted for a ROI
    which contains predominantly the corresponding dye.
  • Manually: the user is prompted for the emission spectrum
  • Library spectrum: If the spectra library is set up correctly and contains spectra, these spectra
    are available at the bottom of the pull down menu.

If the user selected items that require further user input such as ROIs or numbers,
additional dialogs will appear after closing the parameter dialog.

Keep spectra fixed?
If some spectra are known accurately, one can fix them during the optimization and iterate only the remaining spectra. To keep the spectrum of a dye fixed, check the appropriate boxe. If all dyes are kept fixed, poissonNMF updates only the concentrations and thereby produces a non-negative iterative linear unmixing of the signal. This unmixing differs from standard least squares unmixing by assuming Poisson noise.

Specify spectral channels?
PoissonNMF does not need to know the boundaries of the spectral channels for the core optimization. It does, however, rely on this information to display the spectra and read spectra from the spectra library. If this option is checked, the user will be prompted for a dialog where the channel boundaries can be entered.

top

Results Panel

After closing the parameter dialog and providing the optional input, the plugin can decomposes the image stack. While the plugin is running, it continuously displays
the current spectra and the progress of the calculation in ImageJ toolbar. The
plugin can be cancelled at any time. Furthermore, the current spectra can be used to produce a least square solution of the entire stack.

Once poissonNMF has completed the optimization loop, it displays an image stack
containing the label distributions. Different labels correspond to different values of the third dimensions, with all other dimensions being the same as the input data stack. PoissonNMF also opens a dialog with six buttons for further processing of the results.
The button RGB overlay allows to produce a RGB of the current slice of the stack. The user is asked for an assignment of dyes to color channels.  NMF_results_window

The button background map presents the user a RGB image of the current slice, pixels classified as background are blue, those used for poissonNMF are green and saturated pixels are red. Furthermore, the user can save the estimated spectra and display the background spectrum. The simplex projection is described below.
top

Simplex projection

NMF_simplexThe relative concentrations of up to three dyes can be represented in a two dimensional plane — a representation that we call simplex projection.  Clicking on “Simplex projection” in the results panel opens a separate window which shows the simplex projection, see example on the right. Each white dot represents the relative concentrations at a pixel of the image, while the vertices of the triangle correspond to pixels that are pure according to the currently estimated spectra. Since all concentrations have to be positive, all data points should lie inside the triangle and the triangle should in most cases be tight around the cloud of data points. Sometimes, however, PoissonNMF has not found a strictly positive or a sparse solution. In this case, the corners of the triangles can be moved with mouse for manual post-processing of the PoissonNMF result. After moving them with the mouse, the concentrations and the simplex projection are recalculated. This can be iterated until the triangle of pure dyes contains all data tightly. Note that the simplex projection presented here and employed in [2] has some similarity to the plugin spectral phasor.

Spectra Library

PoissonNMF can use literature spectra or spectra determined in previous runs, for example as start spectra or as fixed spectra while optimizing other unknown spectra. For a spectrum to be available in PoissonNMF, it has to be placed in the folder SpectraLibrary located in the plugins folder of ImageJ. The files are assumed to be text files with the wavelength in column one and the emission in column two, conform with the output format of PoissonNMF. Files containing emission spectra have to end on .emn.
A sample library of spectra can be found here.
top

References

  1. D.D. Lee and H.S. Seung. Learning the parts of objects by non-negative matrix factorization. Nature, 40:788-791, 1999.
  2. R.A. Neher, M. Mitkovski, F. Kirchhoff, E. Neher, F.J. Theis, and A. Zeug. Blind source separation techniques for the decomposition of multiply labeled fluorescence images. Biophysical Journal, vol. 96 (9) pp. 3791-800, 2009.

top

Advertisements

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s